Eaton BR series loadcenter accessories — ground bars, filler plates, handle ties, interlocks, and more. Source: Eaton CA08100002E (Nov 2022).
Handle tie bar — joins handles of two adjacent single-pole BR breakers (metal pin type)
Handle tie — joins two independent outside poles of BQ/BQC quadplex or outside poles of two BD duplex breakers
Handle tie — joins two adjacent outside poles of BQ/BQC quadplex or outside poles of two BD duplex breakers
Padlockable lockoff — single-, two-, or three-pole BR breakers, or single-pole BD duplex / one outside pole BQ/BQC (escutcheon mounted)
Padlockable lockoff — single-pole BR breaker (handle mounted)
Padlockable lockoff — two- and three-pole BR breaker (handle mounted)
Padlockable lockoff — single-pole BD duplex, BQ or BQC quadplex (handle mounted)
Padlockable lockoff — center and outer poles of BQ/BQC quadplex (escutcheon mounted)
Padlockable lockoff — BR long body AF/GF breakers ON or OFF position
Padlockable lockoff — BR short body BRCAF/BRAFGF/QBCAF/QBAFGF breakers ON or OFF
Padlockable lockoff — CC/CCH main breaker ON or OFF (screw mounted)
Padlockable lockoff — BW/CSR main breaker ON or OFF (escutcheon mounted)
Lockdog — secures handle ON or OFF for BR breakers, single-pole BD duplex, or one outside pole BQ/BQC (escutcheon mounted)
Lockdog — single-pole BR breaker (handle mounted)
Lockdog — two- and three-pole BR breaker (handle mounted)
Lockdog — single-pole GFTCB ground fault breaker (handle mounted)
Lockdog — one outside pole BQ/BQC quadplex or single-pole BD duplex (handle mounted)
Hold-down retainer kit — three-pole BR breakers in S3100 and 3100R loadcenters only
Hold-down screw kit — two- and three-pole BR breakers in single-phase MLO 100–125A loadcenters
Hold-down screw kit — two- and three-pole BR breakers in MLO 150–200A loadcenters
Hold-down screw kit — two-pole BJ/BJH breakers in MLO 125–225A loadcenters
Hold-down screw kit — three-pole BJ/BJH breakers in MLO 125–225A loadcenters
Retaining bracket for backfed main breaker in BR loadcenter
1-inch filler plates for BR branch breaker slots
Also available as BRFPP (5-pack)
1-inch filler plates — 5-piece multipack
BW main breaker filler plate (with hardware)
CSR main breaker filler plate (gray)
PON ground bar — 5 position, 2.39 in.
PON ground bar — 5 pos + 1 large (2/0), 3.39 in.
PON ground bar — 10 position, 4.05 in.
PON ground bar — 10 pos + 1 large (2/0), 5.05 in.
PON ground bar — 14 position, 5.39 in.
PON ground bar — 14 pos + 1 large (2/0), 6.39 in.
PON ground bar — 21 position, 7.72 in.
PON ground bar — 21 pos + 1 large (2/0), 8.72 in.
Legacy ground bar — 5 position, 2.54 in.
Legacy ground bar — 5 pos + 1 large (2/0), 3.59 in.
Legacy ground bar — 10 position, 4.29 in.
Legacy ground bar — 10 pos + 1 large (2/0), 5.34 in.
Legacy ground bar — 14 position, 5.69 in.
Legacy ground bar — 14 pos + 1 large (2/0), 6.74 in.
Legacy ground bar — 21 position, 8.14 in.
Legacy ground bar — 21 pos + 1 large (2/0), 9.19 in.
100A main breaker — 10 kAIC
Compatible with: Convertible BR loadcenters
125A main breaker — 10 kAIC
Compatible with: Convertible BR loadcenters
125A BW main breaker kit — 10 kAIC, #2–300 kcmil
150A BW main breaker kit — 10 kAIC, #2–300 kcmil
175A BW main breaker kit — 10 kAIC, #2–300 kcmil
200A BW main breaker kit — 10 kAIC, #2–300 kcmil
125A CSR main breaker kit — 25 kAIC, #2–300 kcmil
150A CSR main breaker kit — 25 kAIC, #2–300 kcmil
200A CSR main breaker kit — 25 kAIC, #2–300 kcmil
125A sub-feed lug blocks — 2-pole, #8–2/0
150A sub-feed lug blocks — 2-pole, #8–2/0
150A sub-feed lug blocks — 3-pole, #8–2/0
225A sub-feed lug blocks — 2-pole, #2–300 kcmil
225A sub-feed lug blocks — 3-pole, #2–300 kcmil
200A stud-mounted main lugs — includes deadfront filler plate, #1–300 kcmil
200A/225A replacement main lugs — PON MLO or convertible (#1–300 kcmil)
Gutter tap kit for riser panels — 250 kcmil
Mechanical interlock kit — PON BR loadcenters with backfed BR main breaker
Order BRPHD hold-down kit separately for generator breaker. Not for legacy BR panels.
Bulk pack (10) — PON BR loadcenters with backfed BR main breaker
Mechanical interlock kit — PON BR loadcenters with CSR main breaker
Order BRPHD hold-down kit separately. Not for legacy BR panels.
Bulk pack (10) — PON BR loadcenters with CSR main breaker
Mechanical interlock kit — legacy BR loadcenters with backfed BR main breaker
Bulk pack (10) — legacy BR loadcenters with backfed BR main breaker
Mechanical interlock kit — legacy BR loadcenters with CSR main breaker
Bulk pack (10) — legacy BR loadcenters with CSR main breaker
Mechanical interlock — for two-, three-, and four-pole BR breakers
NOT suitable to transfer emergency power
Cover replacement latch — indoor loadcenters (gray)
Cover replacement latch — indoor loadcenters (white)
Door replacement latch — outdoor (NEMA 3R) loadcenters
Cover replacement latch — 14-5/16 in. wide loadcenters only (legacy)
Keyed door lock — 12–42 circuit, 100–225A loadcenters
Door lock — 4–8 circuit, 125A loadcenters
Cover mounting screws (standard)
Cover mounting screws (white)
Spray paint — 12 oz can (white)
ANSI-61 light gray touchup paint — current outdoor loadcenters
Circuit marking strip for BR loadcenter cover/door
3/4 in. conduit hub — Group 1 (70/100/125A loadcenters)
1 in. conduit hub — Group 1 (70/100/125A loadcenters)
1-1/4 in. conduit hub — Group 1 (70/100/125A loadcenters)
1-1/2 in. conduit hub — Group 1 (70/100/125A loadcenters)
2 in. conduit hub — Group 1 (70/100/125A loadcenters)
2 in. conduit hub — Group 2 (150/200/225A loadcenters)
2-1/2 in. conduit hub — Group 2 (150/200/225A loadcenters)
3 in. conduit hub — Group 2 (150/200/225A loadcenters)
Adapter kit — install Group 1 hub on Group 2 knockout
Blank closure plate — Group 1 (small)
Blank closure plate — Group 2 (large)
Bonding kit — bonds neutral bus to PON loadcenter enclosure
Bonding strap with screw
Isolated neutral assembly — computer circuits
Incoming 2/0 neutral lug (PON)
Incoming 300 kcmil neutral lug (PON)
Add-on neutral/ground lug — 2/0 max (legacy)
Add-on neutral/ground lug — 3/0 max (legacy)
Add-on neutral/ground lug — 300 kcmil max (legacy)
5-circuit terminal block for renovation
Circuit directory — (2) 42-circuit cards, (2) adhesive plastic sleeves
Circuit directory — adhesive backed
Circuit identification labels — preprinted breaker labels
Series rating caution label
Terminal insulator kit — CSR/CSH/BW/BWH mains
Terminal insulator kit — CH/BR/BRH/BRHH/BRX mains