Panel Schedule Generator

Generate professional electrical panel schedules from project material lists with circuit descriptions and breaker information.

Select Panel

Main Breaker: 200A
Bus Rating: 225A
Spaces: 40
Voltage: 120/240V
Location: Garage

Panel Summary

Total Circuits:26
Used Circuits:23
Spare Circuits:3
Spaces Used:32 / 40
Total Load:294A
Load %:147.0%

Actions

Panel A (Main)

Panel Size:
Catalog Number:Auto-picks plate size
Plate Size:
Main Breaker
200A
Bus Rating
225A
Voltage
120/240V
Location
Garage

Live Preview

Final Product
5×7 engraving · updates as you edit
Panel A (Main)Main 200A • Bus 225A • 120/240V • 1Ø, 3W • 32 ckt#DescriptionBrkrPF1Kitchen Counter Outlets…20ASPG3Kitchen Appliance (Dish…20ASPG5Laundry Room Outlets20ASPG7Master Bedroom Outlets20ASPA9Guest Bedroom Outlets15ASPA11Living Room Outlets20ASPA13General Lighting (First…15ASP15Garage Outlets20ASPG17Outdoor Outlets (Front)20ASPG19A/C Condensing Unit30A2P21Electric Range50A2P23Electric Dryer30A2P25Water Heater40A2P27EV Charger (Future)50A2P29SPARE20ASP31SPARE20A2P#DescriptionBrkrPF2Kitchen Counter Outlets…20ASPG4Kitchen Appliance (Disp…20ASPG6Laundry (Washer)20ASP8Master Bathroom20ASPG10Guest Bathroom20ASPG12Dining Room Outlets20ASPA14General Lighting (Secon…15ASP16Garage Door Opener15ASP18Outdoor Outlets (Back)20ASPG202224262830SPARE20ASP32

This is exactly what gets exported — edit circuits, breaker sizes, or panel size below and the preview updates instantly. When it looks right, use Generate PDF or SVG for Aluminum Engraving.

Odd Circuits (Left)
#DescriptionBrkrPFeat
1Kitchen Counter Outlets (North)
GFCI
3Kitchen Appliance (Dishwasher)
GFCI
5Laundry Room Outlets
GFCI
7Master Bedroom Outlets
AFCI
9Guest Bedroom Outlets
AFCI
11Living Room Outlets
AFCI
13General Lighting (First Floor)
Std
15Garage Outlets
GFCI
17Outdoor Outlets (Front)
GFCI
19A/C Condensing Unit
Std
21Electric Range
Std
23Electric Dryer
Std
25Water Heater
Std
27EV Charger (Future)
Std
29Spare
Std
31Spare
Std
Even Circuits (Right)
#DescriptionBrkrPFeat
2Kitchen Counter Outlets (South)
GFCI
4Kitchen Appliance (Disposal)
GFCI
6Laundry (Washer)
Std
8Master Bathroom
GFCI
10Guest Bathroom
GFCI
12Dining Room Outlets
AFCI
14General Lighting (Second Floor)
Std
16Garage Door Opener
Std
18Outdoor Outlets (Back)
GFCI
20— empty —
22— empty —
24— empty —
26— empty —
28— empty —
30Spare
Std
32— empty —

Circuit Types

Breaker Types

SP - Single Pole (120V)
2P - Two Pole (240V)
3P - Three Pole (208V/480V)

Special Features

AFCI - Arc-Fault Protection
GFCI - Ground-Fault Protection
DUAL - AFCI/GFCI Combined
HID - High Intensity Discharge

Load Calculation

Enter actual load in amps
Leave blank for 0A load
Panel load = sum of all circuits
Keep under 80% of main breaker